To use IBM Cognos product documentation, you must enable JavaScript in your browser.

Upgrading Transformer Models and PowerCubes

You can open IBM Cognos Series 7 models with secured cubes in Transformer and upgrade the IBM Cognos Series 7 user class views and user classes for use in IBM Cognos 8.

Before you load the model, the IBM Cognos Series 7 namespace must be configured in IBM Cognos 8 .

To upgrade Transformer models and PowerCubes, do the following:

      

Prepare the IBM Cognos Series 7 models

      

Import unsecured models in IBM Cognos 8 Transformer

      

Upgrade IBM Cognos Series 7 secured PowerCubes in IBM Cognos 8 Transformer

Prepare Models in IBM Cognos Series 7 Transformer

To upgrade models created in earlier versions of Transformer, you must save them in Model Definition Language (MDL) format before you can import them into Transformer 8.4. This ensures that equivalent definitions are created for all model objects. You can upgrade models from IBM Cognos Series 7 Transformer, versions 7.x.

Steps
  1. Open the model in the earlier version of Transformer and, from the File menu, click Save As.

  2. In the Save as Type box, click Exported Model Files (*.mdl).

    Tip: By default, Transformer saves models in the ../My Documents/Transformer/Models directory. You can set the location to which Transformer saves models by changing the Models directory setting on the Directories tab of the Preferences property sheet.

  3. Back up the .mdl files in a secure location.

Import Unsecured Models in IBM Cognos 8 Transformer

After you install IBM Cognos 8 Transformer, you can import the .mdl files from IBM Cognos Series 7 into IBM Cognos 8 Transformer. If you are importing secured models from IBM Cognos Series 7, see the topic about upgrading an IBM Cognos Series 7 secured model in Transformer 8.4.

You can open an IBM Cognos Series 7 model with secured cubes in IBM Cognos 8 Transformer, and convert the IBM Cognos Series 7 user class views to IBM Cognos 8 custom views. You can then choose the authentication provider you want to use with the custom views. For more information about adding security, see the Transformer User Guide.

During the transition from an IBM Cognos Series 7 namespace to an alternate security provider, you can use the PowerCube property All applicable namespaces (including unsecured PowerCubes) to associate all applicable namespaces during migration testing. When you associate all the applicable namespaces to the cube, you can ensure that the group, role, or user dimensional filtering is consistent with that which had been applied for the IBM Cognos Series 7 user class. This option is supported only for migration testing, and cannot be used to deploy cubes in production environments.

You can change the association for an IQD data source to that of an IBM Cognos 8 data source, thereby taking advantage of the enhancements available when using an IBM Cognos 8 package or report data source. You can change the association for IBM Cognos Series 7 .iqd files and for Framework Manager .iqd (externalized query) files, after the updated model has been saved in Transformer 8.4. For more information about changing a data source type, see the Transformer User Guide.

Transformer 8.4 supports upgrading models from IBM Cognos Series 7.x. When importing .mdl files from earlier versions, some features may not convert correctly, such as legacy data that contains special characters, spaces, and quotation marks. For more information, see the migration documentation delivered with your version of the product.

Step

Upgrade an IBM Cognos Series 7 Secured PowerCube

You can open IBM Cognos Series 7 models with secured cubes in IBM Cognos 8 Transformer, and upgrade the IBM Cognos Series 7 user class views and user classes for use in IBM Cognos 8.

If you want to move to an IBM Cognos 8 supported authentication provider other than Access Manager, you can do this over time.

When you open the IBM Cognos Series 7 secured model in IBM Cognos 8 Transformer, you can choose to:

For PowerCubes that are in development and transitioning from an IBM Cognos Series 7 namespace to an alternate security provider, you can associate all the applicable namespaces on the PowerCube property sheet (Data Source tab). This option is intended only for the testing of migration, and requires that the modeler or administrator log on to all the applicable namespaces prior to accessing the PowerCube package in IBM Cognos 8. Failing to log on to all applicable namespaces will result in an inaccurate view of the data. This feature is not supported for the deployment of cubes for end users.

For more information about publishing a PowerCube, see the Transformer User Guide.

Steps
  1. From the File menu, click Open, browse to the location of the IBM Cognos Series 7 secured model, select the model, and then click Open.

  2. In the Import model with IBM Cognos Series 7 user class view dialog box, select the appropriate security import option, and then click Next.

  3. If you selected Import user class views and user classes from the model, in the Logon dialog box, select the appropriate namespace and then log on with your user ID and password.

  4. In the Available namespace(s) box, select the namespace used to secure the IBM Cognos Series 7 cube.

    Tip: If the namespace does not appear in the list, click Logon As to select and log on to the namespace.

  5. Click Finish.